Change storage location for serial in quality inspection stock
Hi, We need solution for change storage location for serial number that in quality inspection stock (before usage decision and after migo).Tcode qac2 not for serial number. What about ie02 ?Any...
View ArticleWIP batch with QM inspection
Hi, Has anyone successfully implemented QM inspection with WIP batch. I have been trying to integrate but cannot find a way to book WIP batch stock out of Q stock. Below is the process we follow....
View Articlestock inconsistency means
Dear experts, Any one can explain stock inconsistency between mm and qm.please give me detailed explaination where we will find such kind of scenarios Alread i had gone through different threads which...
View ArticleTo deactivate field SCRAP posting after UD
Dear Pundits, Please help me out. Client wants to deactivate the field RQEVA-VMENGE02 (SCRAP Posting) in Usage decision.Can this be done by functional personnel if YES?? If not what specification...
View ArticleAvailability of final product after control
Hello, We have the following scenario : Production is done and then we need about 5 days to control the material. However, the production is running 7/7 24/24, but the lab does run only 3/7 from 8am to...
View ArticleBapi to change the workcenter for CRQ2
Hi Experts,I want to change record for CRQ2 using function module. I found one FM CRAP_WORKCENTER_CHANGE. I passed the inputs and i tried to change the description IN_CRHD_API01-ktext = 'sample text'...
View Articlecreating inspection lot during goods issue?
We have an interface between our custom PP system and SAP MM such that the PP system's 'production order' (repeat: NOT in SAP) generates a GI to cost center in SAP. 100% of all these pick requests are...
View ArticleCannot archive a Batch Record
Hi, I'm trying to do de UD for an Inspectio lot but the system doesn't allow me because I need to approve the batch record first but when I try to archive the batch record (via COEBR) to be able to...
View ArticleDefault Bin for Movement type 655
Hello Everyone, I am new to QM configurations and need help. We create return sales order and delivery and PGI it so we get the entry on QA32 to make usage decision. Once Usage decision is accepted,...
View ArticlePlant specific code groups in QM01
Hi Team In QM01, we enter notification type and then plant and on item screen when we press F4 help, code groups for all plants are displayed, where we can make setting that after entering plant only...
View ArticleSample size double thant formula result
Hi, I've configured a formula (square root (N) + 1) but when the inpection lot is created the sample size is doble than should be. At the example below, the sqare root for a 2000 units inspection lot...
View ArticleRequired automatic QM notification generation when result recorded for an MIC...
Hello experts,In my project, we are doing equipment calibration in SAP PM and the process is such that when PM plan is scheduled, a PM order and an inspection lot gets generated automatically.The next...
View ArticleScheduling Problem In Stability Studies.
Dear Guru's, I have a issue in Scheduling in Stability Studies. I am fessing a error at the time of scheduling.When we scheduled a Batch for Stability, One Package has short come, like if system date...
View ArticleLot origin 10 / Physical sample
Dear experts, Please i'm looking for a solution for creating physical samples during quality inspection for outbound delivery (origin 10). At the moment of sample size calculation, the system displays...
View ArticleQA07 - Do not transfer to blocked stock
Hi all ; I have a batch that is exceeded shelf life expiration date. When i execute QA07 , batch is not transfer to blocked stock . Stock is unrestricted usage.Not in special stock type.Storage...
View ArticleDifference of Q-info and vendor in Inspection plan Material Assignment
Hi QM experts, Could you please tell me the Difference of Q-info and vendor in Inspection plan Material Assignment? Q-info:vendor in Inspection plan Material Assignment:Regards,Steve
View ArticleReport required for PM work order, Inspection lot and UD
Hello Experts,In my project, we are doing calibration/Inspection work orders for PM equipments, such that on releasing the PM order an Inspection lot # gets generated against which we do result...
View ArticleFollow-up function In QA11 changing equipment status to NPRT when UD is...
Hello Experts,I am working with follow up function while entering usage decision in Inspection lot. My inspection lot is for Inspection/calibration of PM equipment. My follow up action contains the FM...
View ArticleQA33- Modification needed
In QA33 selection screen I need to have an ICON (Custom) at the top .when clicked it should bring an input screen. Upon data input into that input screen , it should populate a list of numbers stored...
View ArticleGenerating the COA for non-batch managed serialized materials
Hello QM Guru's, I have a requirement to generate a COA for a material that is not batch managed but serialized along with the serial numbers and results. Here are the steps that I followed: 1. Created...
View Article