Hi,
I have created a sampling drawing procedure with following parameters..
Primary Samples: Fixed number 5 and size factor 2
Pooled Samples : Fixed number 2 and size factor 2
Reserve samples : Fixed number 1, sample qty 100 g, sample unit G
For a raw material I have created a inspection plan and assigned above sampling drawing procedure and also made all the relevant master data settings...Now created Purchase Order for qty 500 KG , then made GR for the PO then inspection lot got generated and physical samples got generated as below....
Now I am ok with no of Reserve sample i.e.1 and sample size of 100 G.....everything fine in case of Reserve sample
Coming to No of Primary samples are 5, that is fine but how system calculated sample size as 80 G for each.....
Coming to No of Pooled samples are 2, that is fine but how system calculated sample size as 100 G for each.....
can any body explain how system calculates qty's of physical samples sizes....and also overall inspection lot sample size is 0.500 KG ..How this is calculated...plz explain.....
Thanks