Quantcast
Channel: SCN : Discussion List - SAP ERP Operations - Quality Management (SAP QM)
Viewing all articles
Browse latest Browse all 2825

Query in Classed recording in MIC

$
0
0

Dear Experts,

 

I am trying to explore the feature "Classed recording" for an Quantitative MIC. I referred QM expert Craig's earlier post on classed recording topic. But i am having fundamental doubts in this topic.

 

I have created a Quantitative MIC with the below data

 

Lower spec. limit - 29 mm

Upper spec. limit - 31 mm

Target spec. limit - 30 mm

No of classes -      2

Class width -         0.5mm

Class midpoint -    30 mm

 

I have assigned the MIC in inspection plan and i have created the Inspection lot for the lot qty of 30 Ea with inspection type 89. While performing the result recording for the inspection plan the below

 

ClassLower Class limitUpper class limitClass sizeValuation
114.529.5Rejected
229.530Accepted
33030.5Accepted
430.562Rejected

 

 

But i was expecting only 3 class will be created as given below.. Is my understanding is correct?

ClassLower Class limitUpper class limitClass sizeValuation
12929.5
229.530
33030.5

 

 

My queries are given below

 

1. How the Lower class limit for class 1 is calculated as 14.5 ?

2. How the Upper class limit for class 4 is calculated as 62?

3. How the Valution is showing automatically as "Accepted" and "Rejected"?

4. How to update the results for this scenario in column "Class size" ?

 

Please provide your inputs for my understanding on this issue